The lede: the outage can kill more people than the storm

Hurricane Laura hit Louisiana in August 2020 with 150 mph winds. Of the 28 deaths Louisiana counted, almost all came after the storm had passed, and half of them, 14, were carbon monoxide poisoning from generators. Carbon monoxide is a poison gas in engine exhaust that you cannot see or smell.

A year later Hurricane Ida knocked out power to all of New Orleans in late-summer heat. On September 8, 2021, the city added 11 deaths to Ida’s toll. Nine were from heat during the outage, all people 64 to 79 years old.

Winter is no different. In the February 2021 Texas freeze, generators caused more than half of the known carbon monoxide deaths tied to the outage. Across the country, about 85 to 100 Americans die every year from portable generator exhaust, and the deaths spike in the days after big storms, when coverage is winding down.

A line you can use: “The wind gets the headlines. The outage that follows is what kills people, and it starts after the cameras leave.”

Six facts that change the story

Story ideas that haven’t been done to death

Questions to put to officials

Why people run generators in the garage: they’re afraid it will be stolen

“Never run a generator indoors” is in every storm story. Many of the people who die had heard the warning. Emergency crews in Texas say it plainly: people often run the generator in the house or garage because they’re worried it will be stolen. A mid-size portable generator costs around $1,000, and after a storm every one in the neighborhood is worth stealing.

That’s a problem with a cheap fix, and it’s almost never in the coverage:

A line you can use: “Most people who run a generator in the garage know better. They’re afraid it’ll walk off. Tell them to chain it outside, 20 feet from the house.”

The safety feature to look for on the box

Many new portable generators carry a carbon monoxide sensor that shuts the engine off when the gas builds up around it. Makers give it brand names: Generac calls it COsense, Champion calls it CO Shield. Two industry standards cover it. Generators certified to UL 2201 also burn cleaner, putting out less carbon monoxide in the first place. Generators certified to PGMA G300 shut off but are not held to the lower-exhaust rule. Safety testing has found the UL standard the more protective of the two.

Both standards date from 2018, and many older generators have neither. The useful advice is specific: if you are buying, look for a carbon monoxide shutoff on the box, ideally UL 2201. If yours is older, the alarms and the 20-foot rule are doing all the work.

A line you can use: “If you are buying a generator before this storm, read the box. You want the one that shuts itself off when carbon monoxide builds up.”

The gas math nobody does

Most people don’t need to run a generator around the clock. A refrigerator, a few lights, a fan and phone chargers are a light load, and running the generator in stretches, a few hours on and a few off, keeps the food cold on a fraction of the fuel. That is the advice that matters, because the fuel is the hard part.

“Have fuel on hand” sounds simple until you put numbers on it. A typical 7,500-watt portable generator holds about 7.9 gallons and runs about 10 hours at half load. That is roughly 19 gallons a day.

Outage lengthGasoline at half loadFive-gallon cans
1 dayabout 19 gallons4
3 daysabout 57 gallons12
5 daysabout 95 gallons19
A weekabout 133 gallons27

On propane, the same generator runs about 5 hours on a 20-pound grill tank, so a full day takes about five grill tanks.

Three things make this harder than it looks:

A line you can use: “A portable generator drinks about 19 gallons of gas a day. Ask yourself where that is coming from on day three, when the stations have no power to pump.”

The cord that kills line workers

Some people connect a generator to the house by plugging a homemade cord into a dryer outlet. It is sometimes called a “suicide cord,” and it is worse than that name suggests. It can send the generator’s power backward out to the street, called backfeed, which energizes lines the utility crews think are dead. Line workers have been killed by it. It can also start a fire in the house when the grid power comes back on.

The safe way costs less than people think. An electrician installs an inlet box on the outside wall, where the generator plugs in, and an interlock kit, a sliding metal plate on the breaker panel that makes it impossible to have the utility main and the generator on at the same time. Installed, that usually runs about $400 to $850. A manual transfer switch, which does the same job with a separate small panel, costs a bit more.

A line you can use: “Plugging a generator into a dryer outlet can electrocute the line worker coming to fix your power. An electrician can make it safe, usually for less than the generator cost.”

Flooded basements and downed lines: the water can be live

In 2015 a Maryland mother and her 4-year-old daughter were found on the stairs to their flooded basement, electrocuted. Police found a portable sump pump in the water beside them. They were trying to deal with the flood.

The basement trap. The news reports follow that pattern again and again: someone goes down to deal with the water. In 2014 an Illinois man died changing a sump pump in about 2 feet of basement water after record rain. In 2016 an Indiana woman died after going to clear water from her basement; investigators pointed to a box fan. Every one of them was trying to fix the flooding, not being careless.

It isn’t rare. A study of the past decade’s U.S. hurricane deaths put “power problems and electrocution” at about 11 percent of the indirect deaths, the ones that come from the aftermath rather than the wind and water, nearly as many as carbon monoxide.

On the coast, where houses sit on pilings instead of over basements, the same risk lives in the ground-level garage and storage room, where the freezer, the washer and the extension cords usually are.

Downed lines in the water. A downed line can energize the ground for about 30 to 35 feet around it, farther when the ground is wet, and a line lying in floodwater can electrify the water itself. You cannot tell a live line by looking at it. Stay at least 35 feet back, never walk or drive through water near a downed line, and call 911. A line the utility shut off can also be live again if someone nearby is backfeeding it with a generator.

Don’t become the second victim. During Hurricane Irene in 2011, a man in Spring Valley, New York, was electrocuted trying to help a 5-year-old boy who had gone into a flooded street and touched a wire. The current runs through the rescuer too: anyone who grabs a person in contact with a live line becomes part of the circuit. Don’t touch them or anything touching them. Call 911 and keep everyone back.

A line you can use: “In a flooded basement, the danger is often the pump or the cord sitting in the water. People die trying to fix the flood.”

What a refrigerator actually needs

The food clock: a closed refrigerator keeps food safe for about 4 hours. A full freezer holds about 48 hours, a half-full one about 24, as long as the doors stay shut. After 4 hours without power, refrigerated meat, fish, eggs, milk and leftovers should go.

What gets left out: a refrigerator uses far less power than people think. A modern one uses roughly 1 to 2 kilowatt-hours a day. A kilowatt-hour is the amount of power a 1,000-watt appliance uses in an hour; the yellow label on the fridge gives a yearly number that you divide by 365. A mid-size portable battery power station, around 2 kWh, the kind sold for camping, can carry a full-size refrigerator for about a day, with no fuel, no exhaust and no noise. Run a generator for the fridge and it is mostly burning gas to idle.

A line you can use: “Your refrigerator uses about as much power in a day as a hair dryer uses in an hour. You don’t need a gas engine running all night to keep the milk cold.”

Breathing machines and medicine that has to stay cold

Millions of Americans sleep with a CPAP, a breathing machine for sleep apnea. Many others keep insulin or other medicine in the refrigerator, or use an oxygen machine. For them the outage is a medical problem on the first night, not the third day.

A generator is a poor fit here, and for many apartment renters it isn’t an option at all: there is nowhere to run one 20 feet from the building. Even with a yard, it has to be started, fueled and watched at 3 a.m., and it can’t sit near an open window. A battery with automatic switchover beside the bed keeps the machine running without anyone getting up.

A line you can use: “If someone in the house sleeps on a breathing machine, the outage becomes an emergency the first night. A battery beside the bed covers it.”

Standby generators fail too, usually for a simple reason

A standby generator is the permanent kind that sits on a pad beside the house and starts by itself when the power goes out. Owners tend to think of it as automatic in every sense. The most common reason one fails to start in an outage is a weak or dead starting battery, the same small battery any engine needs.

Running one isn’t cheap either. A common 22 kW standby generator at half load burns about $170 a day in propane or about $87 a day in natural gas. Fuel prices vary by region; those figures use late-2026 national averages.

A line you can use: “A standby generator that skipped its checkup is a lawn ornament. The battery that starts it is the part that fails most.”

Home batteries: the quiet option, and its honest limits

Home battery backup has no engine and no exhaust, so it can sit inside a garage or a building and run while everyone sleeps, with nothing to fuel and nothing to steal from the yard. With solar panels it refills during the day. A single 13.5 kWh home battery averaged about $15,650 installed in early 2026.

The limits belong in the story too. A battery holds a set amount of power. Central air conditioning or electric heat drains it fast, and a long run of cloudy days slows the refill. In a long outage, most battery setups are run on the essentials.

A line you can use: “A generator gives you power as long as you can find fuel. A battery gives you power as long as the sun comes back. Most people would do best with a plan for both.”

Using this page

Use anything here as written or in your own words. Credit is welcome but not required; “Generator Envy” or GeneratorEnvy.com is fine. Our illustrations are free to use with credit; see use our images. For a comment on deadline, email stan@generatorenvy.com with your outlet, your question and your deadline.

Questions people ask

Is it safe to go into a flooded basement?

Not if the water could be touching outlets, cords, appliances, the furnace or the electrical panel. Assume the water is live. Don't stand in water to flip the breaker; call the utility to cut power at the meter, and have an electrician check the house before power goes back on.

How far from the house should a portable generator be?

At least 20 feet, with the exhaust pointed away from doors, windows and vents. Never in a garage, even with the door open. Some manuals say less; go by 20 feet.

How much gas does a portable generator use in a day?

A typical 7,500-watt portable burns about 19 gallons a day at half load, so a five-day outage takes about 95 gallons. Running fewer appliances and running it in stretches cuts that a lot.

Why do people die after hurricanes instead of during them?

In several recent hurricanes, most deaths came after the storm passed, from carbon monoxide from generators and from heat or cold during long outages. After Hurricane Laura, generators killed 14 people in Louisiana, half of the state's toll.

Can I plug my generator into a dryer outlet?

No. A homemade cord into a dryer outlet can send power back out onto the street lines and electrocute utility workers, or start a fire. An electrician can install an inlet box and interlock kit, usually for about $400 to $850.

How long does food last in the fridge without power?

About 4 hours in a closed refrigerator, about 48 hours in a full freezer and about 24 in a half-full one. After 4 hours, throw out refrigerated meat, fish, eggs, milk and leftovers.