Three things decide what home solar is worth, and a homeowner controls none of them.

In short: Net metering is still a good deal where the power company pays full retail credit for the solar power you send back. That credit has been cut in many states, the rules keep changing, and net metering does nothing in a power outage. Power you use and store at home is the one part of solar’s value those rules can’t touch.
Three things decide what home solar is worth over its life: the price of power, the power company’s rules for solar, and whether the grid stays up. A homeowner controls none of them. Solar panels last 25 years or more, while net metering rules in many states have changed every few years. Power you use and store at home is the one part of solar’s value that does not depend on those rules, and with a battery it keeps working when the grid goes down.
| What you can’t control | What you can control |
|---|---|
| The price of power | How much power you buy |
| Net metering and solar rules | How much of your solar you need to sell back |
| When the grid goes down | How much backup power you have |
Net metering is a billing arrangement. When your solar panels make more power than your home uses, the extra goes onto the grid and your power company credits your bill. Under the original rules, that credit matched the retail price you pay for power, one for one.
Net billing is the newer version many power companies use. Power you use as it is made still saves the full retail price, but power you send to the grid earns a lower export rate.
| Plan | What exported power earns | When it is settled |
|---|---|---|
| Full net metering | Full retail credit | Credits roll over; leftover after a year often earns a low rate |
| Monthly netting | Full credit within the month; a low rate for what is left at month’s end | Every month |
| Net billing | A lower export rate, often changing by the hour | As the power is exported |
Where full net metering is still offered, it is usually the best deal for solar without a battery. The question is how long it lasts.
Say power costs 20 cents per kWh and your panels make 10 kWh more than the house needs.
The $1.80 is the value of the energy only. A battery costs money to buy and install, so where full net metering is offered, sending power back can save more than storing it, and the battery is bought for backup power rather than bill savings. Where power costs more in the evening under time-of-use rates, which charge more during busy hours, stored power can be worth more than power used at midday.
The average U.S. home paid 13.15 cents per kWh in 2020 and 17.30 cents in 2025, and prices are expected to keep climbing in 2026. Demand for power is at record levels, driven largely by new AI data centers, which use as much electricity as small cities. On the regional grid that stretches from Illinois to North Carolina, new data center demand added an estimated $9.3 billion to the cost of reserving enough power plants for 2025 and 2026, a cost that is passed on to customers’ bills. Economists still argue over how much data centers have raised prices nationwide, but the demand keeps growing.
Rising prices make every kilowatt-hour you make and use yourself worth more. They do not raise what most export plans pay for the power you send back.
Power companies and regulators argue that full retail credits shift grid costs onto customers who don’t have solar, and that power exported at midday is worth less than power used in the evening. Solar groups dispute how large that shift is. For homeowners the result is the same in many states: credits for exported power are falling.
Yes, over time. Existing customers are usually kept on their old rules for a set number of years, called grandfathering. When that period ends, they move to whatever plan is in place then.
Changing a grandfathered system can matter too. California customers on the older plans face limits on how much they can expand their systems. Ask your power company before adding panels or a battery.
The homeowners with the most at stake are the ones who sized a large roof system to sell power back and never added a battery. Their savings depend on a credit rate that has an end date, and their panels shut off when the grid goes down.
More than a third of U.S. states have rewritten their net metering rules in the past ten years. Most of the changes pay less for exported power, add monthly charges, or tie the credit to the time of day. Rules can also hold steady: Virginia regulators rejected deeper cuts in 2026.
| Where | What changed | What extra power earns now |
|---|---|---|
| California (its three largest power companies) | Net billing for new customers since April 2023 | Export credits about 75% to 80% lower on average, and they change by the hour |
| Arkansas | Net billing for new customers since 2024 | Roughly 3 cents per kWh, down from about 12 cents |
| North Carolina (Duke Energy) | Monthly netting and a minimum bill since October 2023. The Bridge Rate closes to new applicants at the end of 2026; new customers after that go on time-of-use. | Leftover at month’s end earns the wholesale rate, about 3.4 cents per kWh in a 2024 example |
| Virginia (Dominion Energy) | New plan approved in 2026 for new customers. Yearly netting kept, plus a $1 monthly fee. Existing customers keep their plan. | Leftover after 12 months earns 5.829 cents per kWh |
Rural electric co-ops and city-owned utilities usually set their own rules, separate from state net metering law.
For many homes, yes, but the system is sized differently. Under full net metering, systems were sized to cover a full year of use, with summer surplus banked for winter. Without it, a system sized for daytime use, plus a battery or loads that can run on extra power (a water heater, an electric vehicle, the thermostat), gets more value from each panel because less power is sold back cheap.
No one can promise it. Home customers averaged 11 hours without power in 2024, nearly twice the yearly average of the decade before, mostly because of Hurricanes Beryl, Helene and Milton. Outage time swings widely from year to year with the weather. The grid’s reliability watchdog, the North American Electric Reliability Corporation, said in November 2026 that the outlook for this winter has improved. Its long-term assessment in January 2026 found 13 of 23 North American areas at elevated or high risk of supply shortfalls over the next five years.
Net metering does nothing during an outage. Most grid-tied solar systems without a battery shut off when the grid goes down, so they stop sending power onto the lines where crews are working. A battery keeps the power on only when it is installed for backup, with equipment that disconnects the house from the grid. A system that runs separately from the grid does the same. More on that in Most new solar still goes dark in an outage.
It depends on its size and how it is wired. Many batteries back up only essential circuits: the refrigerator, lights, internet, a well pump, a gas furnace blower, and medical equipment such as an oxygen machine or the breathing machine many people with sleep apnea use all night. Running central air or an electric dryer takes a much larger system. Most batteries let you set a backup reserve, a share of the charge that is held for outages and never used for daily savings. The full list is in what a battery runs, and for how long.
Use it and store it at home. A common order:
Not for backup power. A system that is fully separate from the grid and feeds the house through a transfer switch never exports power. Credit rates and grandfathering dates do not change what it does. It earns nothing from exports; its value is power you control. It needs no export agreement with the power company, though permit and utility notification rules vary by location. A grid-tied system set to never export is different: most power companies still require approval for it. The ways to bring that power into the house are in how backup power gets into the house.
This post is kept current. When rates or rules change, we update it.
Berkeley Lab counted batteries on 37% of new home solar systems in 2025, and 17% outside California.
Read it →
On a well, no power means no water.
Read it →
On November 9, 1965, one wrongly set safety switch near Niagara Falls left more than 30 million people without power for up to 13 hours.
Read it →
Have a question we did not answer? Write to stan@generatorenvy.com. Stan grumbles, but a real person answers.