Stan the Standby, the Generator Envy mascotGenerator Envy™
Keep the Lights On classroom

The structure: loads and the load path

Dead, snow and wind loads, uplift, footings, and why deeper beams are so much stiffer.

UPPER SCHOOL · MODULE 5 OF 8

The ideas

Worked example

At 115 mph, 0.00256 × 115² = about 34 pounds per square foot. On a 23 by 22 foot roof (506 square feet), that's about 17,000 pounds if all of it acted as uplift. Spread across six posts, about 2,900 pounds each, before the engineer's adjustments. A 2 by 2 by 3 foot footing holds 12 cubic feet of concrete, about 1,740 pounds, which is why anchors, the frame's own weight and the soil all matter too.

Problems

  1. Find the basic velocity pressure at 100 mph and at 130 mph.
  2. A 4x10 beam is actually 3.5 by 9.25 inches and a 4x8 is 3.5 by 7.25. How much stiffer is the 4x10?
  3. What do 24 panels at about 50 pounds each weigh, and what is that per square foot over 506 square feet?
  4. Why does a long beam get spliced over a post and not in the middle of a span?

On the pavilion

Measure the posts, beams and spans. Draw the load path and estimate the dead load on each post. Compare with the stamped drawings if the school has them.

Read it on this site

Questions people ask

Answer

100 mph: about 25.6 psf. 130 mph: about 43.3 psf. A 30% faster wind makes about 70% more pressure.

Answer

(9.25 ÷ 7.25)³ = about 2.1 times stiffer, from 2 extra inches of depth.

Answer

1,200 pounds, about 2.4 pounds per square foot.

Answer

The bending is greatest mid-span. Over a post the joint carries little bending and is fully supported.

Keep reading

Have a question we did not answer? Write to stan@generatorenvy.com. Stan grumbles, but a real person answers.