Load path: panels → rafters → beams → posts → footings → soil. Every link has to carry the load.
Dead load is the weight of the structure; panels are about 2.5 pounds per square foot. Snow load comes from your county's ground snow load. Wind can push down or lift up.
Wind pressure: the basic velocity pressure is about 0.00256 × V² pounds per square foot, with V in mph. The engineer adjusts it for height, terrain, shape and safety factors.
Stiffness: a beam's stiffness grows with the cube of its depth. Deeper beats wider.
Concrete weighs about 145 pounds per cubic foot. Footings resist uplift with their weight and their grip on the soil.
Worked example
At 115 mph, 0.00256 × 115² = about 34 pounds per square foot. On a 23 by 22 foot roof (506 square feet), that's about 17,000 pounds if all of it acted as uplift. Spread across six posts, about 2,900 pounds each, before the engineer's adjustments. A 2 by 2 by 3 foot footing holds 12 cubic feet of concrete, about 1,740 pounds, which is why anchors, the frame's own weight and the soil all matter too.
Problems
Find the basic velocity pressure at 100 mph and at 130 mph.
A 4x10 beam is actually 3.5 by 9.25 inches and a 4x8 is 3.5 by 7.25. How much stiffer is the 4x10?
What do 24 panels at about 50 pounds each weigh, and what is that per square foot over 506 square feet?
Why does a long beam get spliced over a post and not in the middle of a span?
On the pavilion
Measure the posts, beams and spans. Draw the load path and estimate the dead load on each post. Compare with the stamped drawings if the school has them.